Teflon® Isolated Burner
(FID)
VIG
Industries manufactures its own flame ionization detector. All
parts and all related hardware which are exposed to the sample are
made of 316 stainless steel. The inner chamber is lined with
Teflon® to prevent any corrosion or contamination. All electrical
connections use twist type BNC connectors to insure good contact.
Glow plug is located in the exhaust path to insure easy ignition. All
capillaries can be easily removed & replaced by the customer in
the field.
|
 |
Custom Electronics
All electronics, with the exception of the graphical display, are
designed and manufactured by VIG Industries. We take great care in
the selection of components to insure reliable operation.
|
Dual Stage, Stainless Steel Sample
Filter
VIG
Industries manufactures its own dual stage, stainless steel sample filter. The
filter consists of a two piece 316 stainless steel body with 1/8"FNPT on each
end, 60 micron sintered stainless steel element (first stage), 10 micron
sintered stainless steel element (second stage), Teflon seals, and a 316
stainless steel spring. The filter is based on the concept that the first stage
of the filter captures particles 60 microns and larger, and the second stage
captures particles of 10 micron and larger. This method provides for precise,
long lasting service and inexpensive maintenance. Elements as small as 0.2
micron are available upon request (interchangeable).
|
Custom, Heated Sample Pumps
VIG Industries offers its own line of cold and heated
head sample pumps. Pumps are available with flow rates of 5.5L/M and
14L/M. Heated pump heads are manufactured by VIG. Interchangeable
cartridge heaters are included with heated pump heads. All sample
pumps use Teflon diaphragms with Teflon flapper type valves. All
fittings are 316 stainless steel.
|
Digital / Graphical Display
VIG
Hydrocarbon Analyzers feature Optrex's graphical displays. This
display coupled with our microprocessor enables our analyzers to be
controlled completely through the display with a small keypad located
directly below it. The display updates in real time so you never miss
a beat. This user friendly system allows first time users to operate
the analyzer with ease.
|
Stainless Steel Solenoid Valves
All VIG analyzers feature stainless steel solenoids and
custom made manifolds. Stainless steel is used whenever the sample
comes in contact.
|
Heated Oven
VIG heated analyzers all contain an oven. The oven temperature is
precisely controlled by the microprocessor. All components that come
in contact with the sample are kept in the oven to prevent
condensation of moisture and contamination of the detector.
|
Teflon® and Stainless Steel
Tubing
All Teflon® tubing is either of type TFE or FEP for long
lasting, corrosion free service. Tubing is color coded as per what it
is used for. Sample lines are clear so that if there is any
contamination it can be easily seen. Fuel is red, combustion air is
blue, and carrier gas for the methane unit is green. All metal tubing
is made of 316 stainless steel.
|
Column
Methane / non-methane units utilizes a column for separation
of methane from the sample. The column is also made of stainless
steel for long life and contaminate free service.
|
 |